Introduction
If you replace the recoil starter with a non-OEM part, you may have to remove the starter cap. For that, you will need the following additional tools:
- 3/4” deep socket
What you need
Step 1
Remove the recoil starter bolts
- Before you begin, be sure that the engine is powered off and is cool to the touch.
- Use a 10 mm socket to remove the three 24 mm long bolts.
Before you begin, be sure that the engine is powered off and is cool to the touch.
Use a 10 mm socket to remove the three 24 mm long bolts.
1024
Step 2
Remove the recoil starter assembly
- Remove the recoil starter assembly.
Remove the recoil starter assembly.
Step 3
- If you are replacing the assembly with a non-OEM part, you may also have to replace the starter cap.
- Remove the 3/4" bolt with a deep socket.
- This bolt can be very difficult to remove. Use the hook as a bracing point to keep the starter cap from rotating.
If you are replacing the assembly with a non-OEM part, you may also have to replace the starter cap.
Remove the 3/4" bolt with a deep socket.
This bolt can be very difficult to remove. Use the hook as a bracing point to keep the starter cap from rotating.
To reassemble your device, follow these instructions in reverse order.