Introduction

What you need

Step 1

              Motor Brushes               
  • Ensure that the drill is unplugged.
  • Position the drill so that it is on its side.

Ensure that the drill is unplugged.

Position the drill so that it is on its side.

1024

Step 2

  • Remove the brush cap with a flathead screwdriver.

Remove the brush cap with a flathead screwdriver.

Step 3

  • Pry up on the copper brush holder with a screwdriver or spudger.
  • Continue lifting up the copper brush holder to remove the brush.
  • Repeat on the opposite side.

Pry up on the copper brush holder with a screwdriver or spudger.

Continue lifting up the copper brush holder to remove the brush.

Repeat on the opposite side.

Step 4

              Field               
  • Position the the drill upright and remove the four 19mm Torx T15 screws securing the motor cover.

Position the the drill upright and remove the four 19mm Torx T15 screws securing the motor cover.

Step 5

  • Remove the motor cover and withdraw the armature.
  • Take note to not lose the washer that sits on top of the armature.

Remove the motor cover and withdraw the armature.

Take note to not lose the washer that sits on top of the armature.

Step 6

  • Remove the black insulator ring.
  • Remove the two 45mm Torx T15 screws securing the field to the drill.

Remove the black insulator ring.

Remove the two 45mm Torx T15 screws securing the field to the drill.

Step 7

  • Position drill on its side.
  • Remove the four 19mm Torx T15 screws.
  • Remove the two 25mm Torx T27 screws.
  • Remove the top portion of the handle.

Position drill on its side.

Remove the four 19mm Torx T15 screws.

Remove the two 25mm Torx T27 screws.

Remove the top portion of the handle.

Step 8

  • Lift the switch up and away to allow room to work.
  • Uncrimp the wire connector on the yellow field wire attached to the switch to disconnect it.

Lift the switch up and away to allow room to work.

Uncrimp the wire connector on the yellow field wire attached to the switch to disconnect it.

Step 9

  • Lift the field out of the device, feeding the yellow wire through the handle.

Lift the field out of the device, feeding the yellow wire through the handle.

To reassemble your device, follow these instructions in reverse order.

Cancel: I did not complete this guide.

Author

                                      with 2 other contributors 

                    Colby Green                     

Member since: 01/13/2020

183 Reputation

                                      1 Guide authored                  



                       Badges:
                       2

Team

                       South Arkansas Community College, Team S1-G1, Mitchell Spring 2020                        

                                                  Member of South Arkansas Community College, Team S1-G1, Mitchell Spring 2020 



                    SACC-MITCHELL-S20S1G1                     


                                            4 Members                     


                                            4 Guides authored