Introduction
What you need
Step 1
Remove serial port connection
- Loosen the screws on the serial port by turning them counter clockwise by hand.
- After loosening the screws, pull the serial port out.
Loosen the screws on the serial port by turning them counter clockwise by hand.
After loosening the screws, pull the serial port out.
1024
Step 2
Remove Lid
- Lift lid to its vertical position.
- Pull lid straight up to remove it from the scanner.
Lift lid to its vertical position.
Pull lid straight up to remove it from the scanner.
Step 3
Detach plastic latches
- Push the plastic opening tools into the crack between the top and the bottom of the chassis.
Push the plastic opening tools into the crack between the top and the bottom of the chassis.
Step 4
Continue latch detachment
- After placing one plastic opening tool into the slit, slide other plastic opening tools along the slit to detach the top from the bottom of the chassis.
- Go all the way along the chassis until you can lift the upper lid.
After placing one plastic opening tool into the slit, slide other plastic opening tools along the slit to detach the top from the bottom of the chassis.
Go all the way along the chassis until you can lift the upper lid.
Step 5
Fully remove the upper lid
- Do not fully remove the lid until you remove the ribbon cable attached to the front of the upper lid.
- Do this by grabbing the upper lid from the sides and rotating it ninety degrees so it is perpendicular to the bottom lid.
- Grab the ribbon cable and gently pull it out of its slot with your fingers.
- The upper lid can now safely be removed from the bottom lid.
Do not fully remove the lid until you remove the ribbon cable attached to the front of the upper lid.
Do this by grabbing the upper lid from the sides and rotating it ninety degrees so it is perpendicular to the bottom lid.
Grab the ribbon cable and gently pull it out of its slot with your fingers.
The upper lid can now safely be removed from the bottom lid.
Step 6
Locate the bulb
- After opening the chassis, you will see a white bulb spanning the width of the scanner.
- Lift up the black piece of plastic the bulb is attached to from the left hand side until it is perpendicular with the bottom lid of the scanner.
After opening the chassis, you will see a white bulb spanning the width of the scanner.
Lift up the black piece of plastic the bulb is attached to from the left hand side until it is perpendicular with the bottom lid of the scanner.
Step 7
Detach the bulb electrical connection
- Use tweezers to grab the plastic casing the wires are housed in.
- Gently jiggle the plastic back and forth until it can be pulled from its connection.
- Pull the wires out of the circuit board.
- Pull the wires up and out over the top of the plastic housing.
Use tweezers to grab the plastic casing the wires are housed in.
Gently jiggle the plastic back and forth until it can be pulled from its connection.
Pull the wires out of the circuit board.
Pull the wires up and out over the top of the plastic housing.
Step 8
Remove the bulb
- Place the plastic housing back into the bottom lid of the scanner.
- Remove the plastic panel by gently pushing on the plastic latches with a plastic opening tool.
- Pull the bulb and wire out of its plastic casing.
- The bulb is now free to be replaced.
Place the plastic housing back into the bottom lid of the scanner.
Remove the plastic panel by gently pushing on the plastic latches with a plastic opening tool.
Pull the bulb and wire out of its plastic casing.
The bulb is now free to be replaced.
To reassemble your device, follow these instructions in reverse order.
Cancel: I did not complete this guide.
Author
with 4 other contributors
Taylor Nesheim
Member since: 10/11/2011
59 Reputation
7 Guides authored
Badges:
7
+4 more badges
Team
Cal Poly, Team 6-9, Regan Fall 2011
Member of Cal Poly, Team 6-9, Regan Fall 2011
CPSU-REGAN-F11S6G9
2 Members
11 Guides authored