Difficulty

Moderate

Steps

8

Time Required

                          10 - 15 minutes            

Sections

3

  • Device Lid
  • 2 steps
  • Outer Scanner Chassis
  • 3 steps
  • New Bulb
  • 3 steps

Flags

Needs Better Images

Better photos will improve this guide. Help out by taking, editing, or uploading new ones!

Markup Mishap

This guide needs better markups. Help out by correcting or making some markup annotations.

Better Introduction

Improve this guide by completing or revising its introduction.

  • BackMicrotek ScanMaker 5900

  • Full Screen

  • Options

  • History

  • Save to Favorites

  • Download PDF

  • Edit

  • Translate

  • Get Shareable Link

  • Embed This Guide

  • Notify Me of Changes

  • Stop Notifications

Introduction

What you need

Step 1

              Remove serial port connection               
  • Loosen the screws on the serial port by turning them counter clockwise by hand.
  • After loosening the screws, pull the serial port out.

Loosen the screws on the serial port by turning them counter clockwise by hand.

After loosening the screws, pull the serial port out.

1024

Step 2

              Remove Lid               
  • Lift lid to its vertical position.
  • Pull lid straight up to remove it from the scanner.

Lift lid to its vertical position.

Pull lid straight up to remove it from the scanner.

Step 3

              Detach plastic latches               
  • Push the plastic opening tools into the crack between the top and the bottom of the chassis.

Push the plastic opening tools into the crack between the top and the bottom of the chassis.

Step 4

              Continue latch detachment               
  • After placing one plastic opening tool into the slit, slide other plastic opening tools along the slit to detach the top from the bottom of the chassis.
  • Go all the way along the chassis until you can lift the upper lid.

After placing one plastic opening tool into the slit, slide other plastic opening tools along the slit to detach the top from the bottom of the chassis.

Go all the way along the chassis until you can lift the upper lid.

Step 5

              Fully remove the upper lid               
  • Do not fully remove the lid until you remove the ribbon cable attached to the front of the upper lid.
  • Do this by grabbing the upper lid from the sides and rotating it ninety degrees so it is perpendicular to the bottom lid.
  • Grab the ribbon cable and gently pull it out of its slot with your fingers.
  • The upper lid can now safely be removed from the bottom lid.

Do not fully remove the lid until you remove the ribbon cable attached to the front of the upper lid.

Do this by grabbing the upper lid from the sides and rotating it ninety degrees so it is perpendicular to the bottom lid.

Grab the ribbon cable and gently pull it out of its slot with your fingers.

The upper lid can now safely be removed from the bottom lid.

Step 6

              Locate the bulb               
  • After opening the chassis, you will see a white bulb spanning the width of the scanner.
  • Lift up the black piece of plastic the bulb is attached to from the left hand side until it is perpendicular with the bottom lid of the scanner.

After opening the chassis, you will see a white bulb spanning the width of the scanner.

Lift up the black piece of plastic the bulb is attached to from the left hand side until it is perpendicular with the bottom lid of the scanner.

Step 7

              Detach the bulb electrical connection               
  • Use tweezers to grab the plastic casing the wires are housed in.
  • Gently jiggle the plastic back and forth until it can be pulled from its connection.
  • Pull the wires out of the circuit board.
  • Pull the wires up and out over the top of the plastic housing.

Use tweezers to grab the plastic casing the wires are housed in.

Gently jiggle the plastic back and forth until it can be pulled from its connection.

Pull the wires out of the circuit board.

Pull the wires up and out over the top of the plastic housing.

Step 8

              Remove the bulb               
  • Place the plastic housing back into the bottom lid of the scanner.
  • Remove the plastic panel by gently pushing on the plastic latches with a plastic opening tool.
  • Pull the bulb and wire out of its plastic casing.
  • The bulb is now free to be replaced.

Place the plastic housing back into the bottom lid of the scanner.

Remove the plastic panel by gently pushing on the plastic latches with a plastic opening tool.

Pull the bulb and wire out of its plastic casing.

The bulb is now free to be replaced.

To reassemble your device, follow these instructions in reverse order.

Cancel: I did not complete this guide.

Author

                                      with 4 other contributors 

                    Taylor Nesheim                     

Member since: 10/11/2011

59 Reputation

                                      7 Guides authored                  



                       Badges:
                       7







                                                        +4 more badges                           

Team

                       Cal Poly, Team 6-9, Regan Fall 2011                        

                                                  Member of Cal Poly, Team 6-9, Regan Fall 2011 



                    CPSU-REGAN-F11S6G9                     


                                            2 Members                     


                                            11 Guides authored