Difficulty
Difficult
Steps
8
Time Required
15 minutes
Sections
2
- Button Plate
- 5 steps
- Power Cord
- 3 steps
Flags
1
Needs Better Images
Better photos will improve this guide. Help out by taking, editing, or uploading new ones!
BackLogitech M125
Full Screen
Options
History
Save to Favorites
Download PDF
Edit
Translate
Get Shareable Link
Embed This Guide
Notify Me of Changes
Stop Notifications
Introduction
The power cord provides connectivity and mouse movement.
If you are having issues getting the mouse to connect properly, or the cord will not retract anymore, consider visiting the M125 troubleshooting page before replacing the part: Logitech M125 Troubleshooting
Be sure to unplug your mouse before proceeding with this guide.
What you need
Step 1
Button Plate
- Turn the device over and remove the two 0.5mm screws near the front of the mouse by using a Phillips #0 screwdriver.
- The black screws used in the Logitech M125 frame are all the same size and do not need special consideration for keeping them separated. Silver colored screws are used on the circuit board and have broader heads.
- Once the screws are removed, open the mouse from the front as it pivots at the rear.
Turn the device over and remove the two 0.5mm screws near the front of the mouse by using a Phillips #0 screwdriver.
The black screws used in the Logitech M125 frame are all the same size and do not need special consideration for keeping them separated. Silver colored screws are used on the circuit board and have broader heads.
Once the screws are removed, open the mouse from the front as it pivots at the rear.
1024
Step 2
- Once the mouse is opened, remove the two black 0.5mm screws located towards the back of the mouse. These are the retention screws for the mouse button plate.
- These screws will also require the Phillips #0 screwdriver.
Once the mouse is opened, remove the two black 0.5mm screws located towards the back of the mouse. These are the retention screws for the mouse button plate.
These screws will also require the Phillips #0 screwdriver.
Step 3
- There are two tabs that further secure the mouse buttons to the frame. They are located on either side of the mouse cord retracting mechanism.
- The tighter confines of the mouse interior will be easier to navigate with metal prying tools. While plastic tools are preferred for most plastic devices, they are too large to access the left tab in the picture.
- To dislodge the tabs, use a prying tool while pressing down on the back of the mouse. When prying, push the tab towards the outside of the mouse.
There are two tabs that further secure the mouse buttons to the frame. They are located on either side of the mouse cord retracting mechanism.
The tighter confines of the mouse interior will be easier to navigate with metal prying tools. While plastic tools are preferred for most plastic devices, they are too large to access the left tab in the picture.
To dislodge the tabs, use a prying tool while pressing down on the back of the mouse. When prying, push the tab towards the outside of the mouse.
Step 4
- To finish removing the button plate, continue lifting the rear of the plate until the tabs have fully left their slots.
- Once the tabs are clear, push the plate towards the front of the mouse and lift.
To finish removing the button plate, continue lifting the rear of the plate until the tabs have fully left their slots.
Once the tabs are clear, push the plate towards the front of the mouse and lift.
Step 5
- The mouse button plate has now been fully removed. In order to install the replacement, follow the instructions for this guide in reverse.
The mouse button plate has now been fully removed. In order to install the replacement, follow the instructions for this guide in reverse.
Step 6
Power Cord
- Using a Phillips #0 screwdriver, unscrew the three black 0.5mm screws from the frame to remove the power cord housing
- Set mouse plate aside after unscrewing the cord housing from the plate
Using a Phillips #0 screwdriver, unscrew the three black 0.5mm screws from the frame to remove the power cord housing
Set mouse plate aside after unscrewing the cord housing from the plate
Step 7
- Unscrew the silver 0.25mm screws to remove the circuit board from the mouse base with the same screwdriver.
- Once unscrewed, remove the circuit board.
- Circuit board needs to be lifted from the front before being pulled forward to remove it
Unscrew the silver 0.25mm screws to remove the circuit board from the mouse base with the same screwdriver.
Once unscrewed, remove the circuit board.
Circuit board needs to be lifted from the front before being pulled forward to remove it
Step 8
- The cable is soldered into the board and will require a soldering iron to replace.
- To continue further, please refer to the following guide on how to solder connectors: How To Solder and Desolder Connections.
- Follow these steps in reverse to reassemble the mouse.
The cable is soldered into the board and will require a soldering iron to replace.
To continue further, please refer to the following guide on how to solder connectors: How To Solder and Desolder Connections.
Follow these steps in reverse to reassemble the mouse.
To reassemble your device, follow these instructions in reverse order.
Cancel: I did not complete this guide.
Author
with 4 other contributors
Bee Pines
Member since: 07/25/2019
97 Reputation
1 Guide authored
Badges:
2
Team
UW Tacoma, Team S1-G2, Liner Summer 2019
Member of UW Tacoma, Team S1-G2, Liner Summer 2019
UWT-LINER-SU19S1G2
5 Members
9 Guides authored